Tel.: +49 241 80 80568
Mechanical Engineering at the RWTH Aachen University
Specialization: Basics - Medical Engineering
since 05/07
Scientific Employee at the Chair of Applied Medical Engineering
Aortic root compliance influences hemolysis in mechanical heart valve prostheses: an in-vitro study. Linde T, Hamilton KF, Cuenca Navalon E, Schmitz-Rode T, Steinseifer U. Int J Artif Organs 2012; 35(7): 495 - 502, Article
A Low-Volume Tester for the Thrombogenic Potential of Mechanical Heart Valve Prostheses. Linde T, Hamilton KF, Timms DL, Schmitz-Rode T, Steinseifer U. J Heart Valve Dis. 2011 Sep; 20(5).
Transient, three-dimensional flow field simulation through a mechanical, trileaflet heart valve prosthesis. Kaufmann TA, Linde T, Cuenca-Navalon E, Schmitz C, Hormes M, Schmitz-Rode T, Steinseifer U. ASAIO J. 2011 Jul-Aug;57(4):278-82.
Comparison of unfractionated heparin, low-molecular-weight heparin, low-dose and high-dose rivaroxaban in preventing thrombus formation on mechanical heart valves: results of an in vitro study. Kaeberich A, Reindl I, Raaz U, Maegdefessel L, Vogt A, Linde T, Steinseifer U, Perzborn E, Hauroeder B, Buerke M, Werdan K, Schlitt A. J Thromb Thrombolysis. 2011 Jul 20, Article
In vitro comparison of dabigatran, unfractionated heparin, and low-molecular-weight heparin in preventing thrombus formation on mechanical heart valves. Maegdefessel L, Linde T, Krapiec F, Hamilton K, Steinseifer U, van Ryn J, Raaz U, Buerke M, Werdan K, Schlitt A. Thromb Res. July 2010, Article.
Sten-based, off-pump creation of an apico-aortic conduit. Spillner J, Hatam N, Amerini A, Otte F, Linde T, Krombach G, Autschbach R, Carpi A, Dohmen G. Frontiers in bioscience (Elite edition) June 2010, Article.
Asynchrony of Disc Impact in Bileaflet Heart Valve Closure Depends on Pressure and Pulse Rate. Linde T, Famaey N, Schmitz-Rode T, Steinseifer U, Meuris B. International Journal of Artificial Organs 2009, Meeting Abstract and Poster.
Argatroban and bivalirudin compared to unfractionated heparin in preventing thrombus formation on mechanical heart valves. Maegdefessel L, Linde T, Michel T, Hamilton K, Steinseifer U, Friedrich I, Schubert S, Hauroeder B, Raaz U, Buerke M, Werdan K, Schlitt A. Thrombosis and Haemostases 2009, Article.
Argatroban and bivalirudin compared to unfractionated heparin in preventing thrombus formation on mechanical heart valves Results of an in-vitro study. Maegdefessel L, Linde T, Michel T, Hamilton KF, Steinseifer U, Friedrich I, Schubert S, Hauroeder B, Raaz U , Buerke M, Werdan K, Schlitt A. Thromosis and Haemostases 2009, Meeting Abstract.
Transient Flow Field Simulation Through a Mechanical Trileaflet heart Valve Prosthesis. Linde T, Kaufmann T, Cuenca-Navalon E, Schmitz C, Schmitz-Rode T, Steinseifer U. International Journal of Artificial Organs 2008, Meeting Abstract and Presentation.
[Development and in vitro Validation of an expandable intravascular Catheter for extracorporeal Oxygenation]. Linde T, Westhohoff F, Schmitz-Rode T, Steinseifer U. DGBMT Aachen 2007. DGBMT Congressjournal und Presentation.