10/03 - 05/09: Mechanical Engineering at the RWTH Aachen University Specialisation: Fundamentals of Mechanical Engineering - Medical Engineering
Work
Since 06/09: Research Assistant at the AME
Publications
Borchardt R; Schlanstein P; Mager I; Arens J; Schmitz-Rode T; Steinseifer U: In Vitro Performance Testing of a Pediatric Oxygenator With an Integrated Pulsatile Pump ASAIO Journal. 58(4):420-425, July/August 2012
Borchardt R, Schlanstein P, Mager I, Arens J, Schmitz-Rode T, Steinseifer U: Experimental and Numerical Results of a Neonatal Oxygenator with Integrated Pulsatile Pump and Heat Exchanger. Int J Artif Organs. 34(8): 624, 2011
Borchardt R; Schlanstein P; Mager I; Arens J; Schmitz-Rode T; Steinseifer U: Experimental Evaluation of an Oxygenator With Integrated Pulsatile Pump for Pediatric Applications. Artificial Organs. 35(4): A17, 2011
Bhavsar S; Seiwert M; Borchardt R; Graefe R; Schlanstein P; Arens J; Schmitz-Rode T; Steinseifer U: Numerical Modeling of Anisotropic Fiber Bundle Behavior in Oxygenators. Artificial Organs. 35(4): A18, 2011
Borchardt R; Hormes M; Schmitz Rode T; Steinseifer U: Numerical Investigation of the Influence of Pulsatile Flow on Gas Exchange Inside an Oxygenator. Artificial Organs. 35(4): A21, 2011
Borchardt R, Schlanstein P, Mager I, Arens J, Schmitz-Rode T, Steinseifer U: Experimental and numerical results of a neonatal oxygenator with integrated pulsatile pump and heat exchanger. Biomedical Engineering. 56, ISSN 0939-4990, 2011
Borchardt R; Schlanstein P; Mager I; Arens J; Schmitz-Rode T; Steinseifer U: In-vitro performance testing of a pediatric oxygenator with integrated pulsatile pump. ASAIO Journal. 57(2): 109, 2011
Hormes M; Borchardt R; Mager I; Schmitz Rode T; Behr M; Steinseifer U: A validated CFD model to predict O2 and CO2 transfer within hollow fiber membrane oxygenators. Int J Artif Organs. 34(3): 317-325, 2011
Borchardt R, Schlanstein P, Arens J, Graefe R, Schreiber F, Schmitz-Rode T, et al. Description of a flow optimized oxygenator with integrated pulsatile pump. Artificial Organs. 34(11):904910, 2010
Schlanstein PC, Borchardt R, Arens J, Schmitz-Rode T, Steinseifer U: Investigation of the influence of pulsating silicone tubes inside an oxygenator. The International Journal of Artificial Organs, vol. 33, iss. 7, p. 423, 2010
Hormes M., Borchardt R., Schmitz-Rode T., Behr M., Steinseifer U. Pulsatile versus non pulsatile blood flow in blood oxygenators: a CFD study. ASAIO Journal. 56(2): 107, 2010
Borchardt R, Schlanstein P, Arens J, Graefe R, Schreiber F, Schmitz-Rode T, et al. Description of a flow optimized oxygenator with integrated pulsatile pump. Artificial Organs. 34(4):A15, 2010
Hormes M., Borchardt R., Behr M., Schmitz-Rode T., Steinseifer U. A Validated CFD Model to Predict O2 and CO2 Transfer within Hollow Fiber Membrane Oxygenators. Int J Artif Organs. 2009;32(7):400401
Hormes M., Kashefi A., Borchardt R., Schmitz-Rode T., Steinseifer U. CFD Simulation Of Oxygen Transfer In Hollow Fiber Oxygenators. Int J Artif Organs. 2008;31(7):641641
Hormes M., Kashefi A., Borchardt R., Schmitz-Rode T., Steinseifer U. A Numerical Model of Oxygen Transfer in Hollow Fiber Oxygenators. ASAIO Journal. 54(2): 63A, 2008